Circuit breaker VK-300
BR11-67U2-21 Electrical engineer ET051925
- Body material: Silumin
- IP degree of protection: ip67
- Interface Execution: Without
- Execution of electrical connection: MG cable gland
- Number of make contacts: 1
- Number of Changeover Contacts: 2
- Number of NC contacts: 1
- Rated current Ie at AC-15, 230 V: 10 A
- Control type: Lever with roller, move to the right, self-return
- Explosion protection category for gas (ATEX EC Directives): Without
- Sensor height: 75 mm
- Sensor length: 60 mm
- Dust explosion protection category (ATEX EC directives): Without
- Suitable for security systems: Yes
- Housing coating: Powder coated
- Ambient temperature during operation: 50 degrees C
- Ambient temperature during operation with: -50 degrees C
- Sensor width: 176 mm
- Manual control: not
- With status indication: not
- Weight g: 756.3
Inquire Now
Description
- PURPOSE
The end (end) switch is intended for switching electrical circuits during mechanical action of the moving part of the equipment on the working part.
- FIELD OF APPLICATION
Automatic machines, conveyor lines, automatic gates and other mechanisms where it is important to turn off the power at the end of the stroke.
- PRINCIPLE OF ACTION
When you press the moving part of the switch (lever, button), the contacts are closed and the circuit is switched. When the mechanical impact ceases, the contacts return to their original state.
- ADDITIONAL ACCESSORIES OR ACCESSORIES
cable for connection, type KVVG.
Limit switch
Nom. number | 8000855814 |
Manufacturer | Software Electrical |
Body material | Silumin |
IP degree of protection | ip67 |
Interface Execution | Without |
Execution of electrical connection | MG cable gland |
Number of make contacts | 1 |
Number of Changeover Contacts | 2 |
Number of NC contacts | 1 |
Rated current Ie at AC-15, 230 V | 10 A |
Control type | Lever with roller, move to the right, self-return |
Explosion protection category for gas (ATEX EC Directives) | Without |
Sensor height | 75 mm |
Sensor length | 60 mm |
Dust explosion protection category (ATEX EC directives) | Without |
Suitable for security systems | Yes |
Housing coating | Powder coated |
Ambient temperature during operation | 50 degrees C |
Ambient temperature during operation with | -50 degrees C |
Sensor width | 176 mm |
Manual control | not |
With status indication | not |
Weight g | 756.3 |